Detalhes
Part no.: YHHC-48B
System: computer controlled system
Standard dies: 16 sets of dies from 1/4’’ to 3’’
Voltage: 380V/50HZ; if other voltage required, please advise us.
Stock available: we have kept many types in stock, then we can ensure the fast delivery.
Tabela de Dados Técnicos
Tipo | YHHC-48B (computer system controlled) |
Crimping range | Φ6—φ76 4SP |
Motor | Y-4/4kw |
Voltage | 380V*50HZ |
Capacity of oil pump | 19L/min |
Pressão sistemática | 30MPa |
Hydraulic oil | Winter :YB-N32 |
Summer :YB-N46 | |
Oil tank volume | 480×440×360mm3 |
L*W*H | 800×650×1350(mm) |
Crimping pressure | 903T |
Nosso serviço
1. Temos muitos agentes em todo o mundo, para que você possa entrar em contato com nosso agente para comprar nossos produtos
2.Technical support any time, Our engineer cellphone:
+86-15158322675
3. tempo de garantia de 3 anos, o cartão de garantia com a máquina junto a você.
Vídeo 4.Supply para aprender a usar máquinas.
5. Door to door service, we are in charge of sending the machine to your office, after payment.fitting ferrule crimping machine
6. podemos projetar máquinas como seu desenho e requisitos. OEM
Perguntas frequentes
Trouble phenomena | Trouble reason | Eliminating method |
Machine has not action | Oil tank has not been filled with oil | Fill oil as per requirement |
Motor rotation direction is not correct | Regulate two phase lines | |
Electric trouble | Overhaul electric circuits | |
Scale is damaged | The scale is fastened on the oil cylinder end face by the screw | Regulate the scale as per the instruction to make scale to telescope freely |
Conductor at scale location is connected with scale | Anew connect the scale conductor to make it to be insulated from scale base | |
Electric trouble | Overhaul electric circuits and electric elements | |
Scale conductor cutting | Anew connect scale | |
System pressure is excessively low | Adjust buckling pressure-regulating valve | |
No buckling | The valve core of solenoid reversal valve is seizured by foreign matters | Dismount solenoid reversal valve, use gasoline to clean the valve core. |
Electric trouble | Overhaul electric circuits | |
Mould is not opened | Opening mould pressure is excessively low | Adjust opening mould pressure regulating valve |
Electric trouble | Overhaul electric circuits | |
Lubrication is poor | Smear grease on the working inclined face of mould base | |
Oil leakage | Joint is not tightened closely | Tighten the oil pipe joint |
Sealing washer is damaged. | Replace sealing washer |