3''-Crimping-Machine

Detalhes


Part no.: YHHC-48B
System: computer controlled system
Standard dies: 16 sets of dies from 1/4’’ to 3’’
Voltage: 380V/50HZ; if other voltage required, please advise us.
Stock available: we have kept many types in stock, then we can ensure the fast delivery.

Tabela de Dados Técnicos

TipoYHHC-48B (computer system controlled)
Crimping rangeΦ6—φ76  4SP
MotorY-4/4kw
Voltage380V*50HZ
Capacity of oil pump19L/min
Pressão sistemática30MPa
Hydraulic oilWinter :YB-N32
Summer :YB-N46
Oil tank volume480×440×360mm3
L*W*H800×650×1350(mm)
Crimping pressure903T

Nosso serviço


1. Temos muitos agentes em todo o mundo, para que você possa entrar em contato com nosso agente para comprar nossos produtos
2.Technical support any time, Our engineer cellphone:
+86-15158322675
3. tempo de garantia de 3 anos, o cartão de garantia com a máquina junto a você.
Vídeo 4.Supply para aprender a usar máquinas.
5. Door to door service, we are in charge of sending the machine to your office, after payment.fitting ferrule crimping machine
6. podemos projetar máquinas como seu desenho e requisitos. OEM

Perguntas frequentes


Trouble phenomena

Trouble reason

Eliminating method

Machine has not action

Oil tank has not been filled with oil

Fill oil as per requirement

Motor rotation direction is not correct

Regulate two phase lines

Electric trouble

Overhaul electric circuits

Scale is damaged

The scale is fastened on the oil cylinder end face by the screw

Regulate the scale as per the instruction to make scale to telescope freely

Conductor at scale location is connected with scale

Anew connect the scale conductor to make it to be insulated from scale base

Electric trouble

Overhaul electric circuits and electric elements

Scale conductor cutting

Anew connect scale

System pressure is excessively low

Adjust buckling pressure-regulating valve

No buckling

The valve core of solenoid reversal valve is seizured by foreign matters

Dismount solenoid reversal valve, use gasoline to clean the valve core.

Electric trouble

Overhaul electric circuits

Mould is not opened

Opening mould pressure is excessively low

Adjust opening mould pressure regulating valve

Electric trouble

Overhaul electric circuits

Lubrication is poor

Smear grease on the working inclined face of mould base

Oil leakage

Joint is not tightened closely

Tighten the oil pipe joint

Sealing washer is damaged.

Replace sealing washer